TEMPLATE Test ValueSet From Template 2 (Test ValueSet From Template 2)

TEMPLATE IDTest ValueSet From Template 2
ConceptTest ValueSet From Template 2
DescriptionNot Specified
PurposeNot Specified
References
Other Details (Language Independent)
  • MetaDataSet:Sample Set : Template metadata sample set
Language useden
Citeable Identifier1013.26.1010
Root archetype idopenEHR-EHR-OBSERVATION.indirect_oximetry.v1
Indirect oximetryIndirect oximetry: Method of monitoring blood gas measurements such as Spo2 and pTCO2 by indirect, currently non-invasive, means.
Data
Any eventAny event: Timing event.
Data
SpO2SpO2: Measured via pulse oximetry, the saturation of oxygen in the peripheral blood.
SpO2 is defined as the ratio of oxyhaemoglobin (HbO2) to the total concentration of haemoglobin (HbO2 + deoxyhaemoglobin).
  • Percent
spOCspOC: Measured via pulse CO-oximetry, the oxygen content of the peripheral blood.
>=0 ml/ml
spCOspCO: Measured via pulse CO-oximetry, the saturation of carboxyhaemoglobin in the perpiheral blood.
  • Percent
spMetspMet: Measured via pulse CO-oximetry, the saturation of methoxyhaemoglobin in the peripheral blood.
  • Percent
ptcO2ptcO2: Measured via transcutaneous electrode oximetry, the partial pressure of oxygen in the peripheral blood.
  • Percent
ptcCO2ptcCO2: Measured via transcutaneous electrode oximetry, the partial pressure of carbon dioxide in the peripheral blood.
  • Percent
Multimedia imageMultimedia image: Details of a series of oximetry readings, other than waveforms, expressed as a multimedia image or series of images. Waveforms should be recorded using the Waveform slot and associated cluster archetype.
CommentComment: A text comment about the indirect oximetry result.
State
Confounding factorsConfounding factors: Comment on and record other incidental factors that may be affect interpretation of the observation. For example, motion, pain, poor perfusion, infant feeding.
Terminology: http://snomed.info/sct
Value set: terminology://fhir.hl7.org/ValueSet/$expand?url=http://hl7.org/fhir/vs/snomed-example-vs
  • 169895004 | Apgar at 1 minute 
  • 169909004 | Apgar at 5 minutes 
  • 169922007 | Apgar at 10 minutes 
Protocol
Sensor siteSensor site: The site of the measurement sensor.
Sensor typeSensor type: The type of measurement sensor used e.g. transmittal, reflective, clamp or strip, electrode.
  •  Coded Text
    • Transmittal 
    • Reflective 
    • Clamp 
    • Strip 
    • Electrode 
  •  Text
Electrode operating temperatureElectrode operating temperature: The operating temperature of a transcutaneous oximeter electrode.
0..100 °C
Time of sensor applicationTime of sensor application: The date and time at which the sensor was applied. Significant for transcutaneous oximetry.