| Root archetype id | openEHR-EHR-OBSERVATION.indirect_oximetry.v1 |
| Indirect oximetry | Indirect oximetry: Method of monitoring blood gas measurements such as Spo2 and pTCO2 by indirect, currently non-invasive, means. |
| Data | |
| Any event | Any event: Timing event. |
| Data | |
| SpO2 | SpO2: Measured via pulse oximetry, the saturation of oxygen in the peripheral blood. SpO2 is defined as the ratio of oxyhaemoglobin (HbO2) to the total concentration of haemoglobin (HbO2 + deoxyhaemoglobin).
|
| spOC | spOC: Measured via pulse CO-oximetry, the oxygen content of the peripheral blood. >=0 ml/ml |
| spCO | spCO: Measured via pulse CO-oximetry, the saturation of carboxyhaemoglobin in the perpiheral blood.
|
| spMet | spMet: Measured via pulse CO-oximetry, the saturation of methoxyhaemoglobin in the peripheral blood.
|
| ptcO2 | ptcO2: Measured via transcutaneous electrode oximetry, the partial pressure of oxygen in the peripheral blood.
|
| ptcCO2 | ptcCO2: Measured via transcutaneous electrode oximetry, the partial pressure of carbon dioxide in the peripheral blood.
|
| Multimedia image | Multimedia image: Details of a series of oximetry readings, other than waveforms, expressed as a multimedia image or series of images. Waveforms should be recorded using the Waveform slot and associated cluster archetype. |
| Comment | Comment: A text comment about the indirect oximetry result. |
| State | |
| Confounding factors | Confounding factors: Comment on and record other incidental factors that may be affect interpretation of the observation. For example, motion, pain, poor perfusion, infant feeding. Terminology: http://snomed.info/sct Value set: terminology://fhir.hl7.org/ValueSet/$expand?url=http://hl7.org/fhir/vs/snomed-example-vs
|
| Protocol | |
| Sensor site | Sensor site: The site of the measurement sensor. |
| Sensor type | Sensor type: The type of measurement sensor used e.g. transmittal, reflective, clamp or strip, electrode.
|
| Electrode operating temperature | Electrode operating temperature: The operating temperature of a transcutaneous oximeter electrode. 0..100 °C |
| Time of sensor application | Time of sensor application: The date and time at which the sensor was applied. Significant for transcutaneous oximetry. |