| ARCHETYPE ID | openEHR-EHR-CLUSTER.timing.v1 |
|---|---|
| Concept | Timing |
| Description | Structured information about the timing (intended or actual) of administration or use of a medicine, other therapeutic good or other intervention that is given on a scheduled basis. |
| Use | For use with medication orders and other instructions where timing is complex and needs to be computable. |
| Misuse | Not to be used for specific timing but for scheduling of tasks that need repeating. |
| Purpose | To provide structured information on timing that is suitable for computation and display for human interpretation. |
| References | Timing, draft archetype, NEHTA Clinical Knowledge Manager [Internet]. : NEHTA. Authored: 21 Nov 2010. Available at: http://dcm.nehta.org.au/ckm/#showArchetype_1013.1.886_4 (accessed 15 May 2013). |
| Copyright | © openEHR Foundation |
| Authors | Author name: Sam Heard Organisation: openEHR Foundation Email: sam.heard@oceaninformatics.com Date originally authored: 2013-05-16 |
| Other Details Language | Author name: Sam Heard Organisation: openEHR Foundation Email: sam.heard@oceaninformatics.com Date originally authored: 2013-05-16 |
| Other Details (Language Independent) |
|
| Keywords | timing, administration, dosing, frequency |
| Lifecycle | CommitteeDraft |
| Language used | en |
| Citeable Identifier | 1013.1.987 |
| items | |
| Daily count | Daily count: This is the actual or maximum number of doses or other interventions that are to be administered in a 24 hour period. |
| Frequency | Frequency: The frequency as number of times per time period that the intervention is to take place. Property: Frequency Units:
|
| Interval | Interval: The length of time between doses or interventions. 8 Hourly is PT8H, monthly is P1M, every hour and a half is PT1H30M. |
| Variable frequency | Variable frequency: Details of variable upper and lower frequency e.g. 3-4 times a day. |
| Upper | Upper: The upper value of frequency. |
| Frequency | Frequency: The frequency as number of times per time period that the intervention is to take place. Property: Frequency Units:
|
| Lower | Lower: The lower value of frequency. |
| Frequency | Frequency: The frequency as number of times per time period that the intervention is to take place. Property: Frequency Units:
|
| Variable interval | Variable interval: Details of variable upper and lower intervals e.g. every 2-3 hours. |
| Upper | Upper: The upper value of the interval. |
| Interval | Interval: The length of time between doses or interventions. 8 Hourly is PT8H, monthly is P1M, every hour and a half is PT1H30M. |
| Lower | Lower: The lower value of the interval. |
| Interval | Interval: The length of time between doses or interventions. 8 Hourly is PT8H, monthly is P1M, every hour and a half is PT1H30M. |
| Specific time | Specific time: Specific time(s) during the day when the intervention should be applied. |
| Day of week | Day of week: The specific and repeating day(s) of the week.
|
| Day of month | Day of month: The specific and repeating day(s) of the month e.g. if it is required to give a dose on the 2nd day of each month then the value is 2. min: >=1; max: <=31 |
| Specific date | Specific date: A specific date when the intervention is to take place. |
| Parsable syntax | Parsable syntax: Complex intervention timing recorded as a parsable syntax. Formalism: text/xml, text/plain |
| Other contributors | Sharmila Biswas, Dr Sharmila Biswas, Australia Stephen Chu, NEHTA, Australia (Editor) David Evans, Queensland Health, Australia Sam Heard, Ocean Informatics, Australia (Editor) Heather Leslie, Ocean Informatics, Australia (Editor) Richard Townley-O'Neill, NEHTA, Australia (Editor) |
| Translators |