| ARCHETYPE ID | openEHR-EHR-OBSERVATION.intravascular_pressure-cvp.v1 |
|---|---|
| Concept | Central venous pressure |
| Description | The central venous pressure (CVP) measures the filling pressure of the right ventricle normally performed by cannulation of the internal jugular vein. |
| Misuse | Not to be used for systemic blood pressure. Use 'observation.blood_pressure' for this. |
| Purpose | To record central venous pressure, normally via cannulation of the internal jugular vein. |
| References | http://www.wwl.nhs.uk/library/foi/clin_pols/cvpprocedures.pdf |
| Copyright | copyright (c) 2010 openEHR Foundation |
| Authors | Author name: Sam Heard Organisation: Ocean Informatics Email: sam.heard@oceaninformatics.com Date originally authored: 28/06/2006 |
| Other Details Language | Author name: Sam Heard Organisation: Ocean Informatics Email: sam.heard@oceaninformatics.com Date originally authored: 28/06/2006 |
| Other Details (Language Independent) |
|
| Keywords | pressure, intravascular, cvp |
| Lifecycle | AuthorDraft |
| Language used | en |
| Citeable Identifier | 1013.1.766 |
| state | |
| Position | Position: Position of patient during measurement. |
| Confounding factors | Confounding factors: Other factors that may interfere with interpretation of the measurement. |
| events | |
| Any event | Any event: Generic event |
| Average over heart cycle | Average over heart cycle: The average over one heart cycle. Math. function: Mean |
| protocol | |
| Device | Device: The device used to record the measurement. Include: All not explicitly excluded archetypes |
| Confounding factors | Confounding factors: Other factors that may interfere with interpretation of the measurement. |
| data | |
| Location | Location: The location of the pressure measurement. Include: openEHR-EHR-CLUSTER.anatomical_ Exclude: All not explicitly included archetypes |
| Pressure | Pressure: The mean pressure measured. Property: Pressure Units:
|
| Relative pressure | Relative pressure: The pressure in relative terms. 0: Markedly reduced [The pressure is much lower than normal or expected.] 2: Lowered [The pressure is reduced.] 4: Normal/expected [The pressure is normal or as expected.] 6: Raised [The pressure is raised.] 8: Markedly increased [The pressure is much higher than normal or expected.] |
| Phase of heart cycle | Phase of heart cycle: The phase of the heart cycle at the time of the measurement
|
| Multimedia | Multimedia: A multimedia representation of the pressure reading, other than waveforms. |
| Waveform | Waveform: A waveform representation of the pressure Include: openEHR-EHR-CLUSTER.waveform.v1 and specialisations Exclude: All not explicitly included archetypes |
| Comment | Comment: A text comment on the reading. |
| Other contributors | Ian McNicoll, Ocean Informatics, United Kingdom |
| Translators |