| ARCHETYPE ID | openEHR-EHR-OBSERVATION.fluid_input.v1 |
|---|---|
| Concept | Fluid Input |
| Description | Record of fluid being ingested by, or administered to, the subject. |
| Use | Use to record details of fluid input as part of routine nursing care. Use to record details of individual fluid input activities, in order to allow fluid balance estimations. For example: "Oral", "Cup of Tea", 220ml; or 1 litre Normal Saline infusion. May also be used to record descriptive assessments of fluid input. A fluid balance chart will typically require a combination of OBSERVATION.fluid_output, OBSERVATION.fluid_balance and this archetype to capture all the required components. |
| Misuse | Not to be used as a primary record of the fluid administration such as intravascular therapy or haemodialyisis. Not to be used to record fluid output. Use OBSERVATION.fluid_output for this purpose. Not to be used to record fluid balance calculations. Use OBSERVATION.fluid_balance for this purpose. |
| Purpose | To record details of fluid input, often used as part of fluid balance estimation. |
| References | |
| Copyright | © openEHR Foundation |
| Authors | Author name: Dr Ian McNicoll Organisation: Ocean Informatics, United Kingdom Email: ian.mcnicoll@oceaninformatics.com Date originally authored: 2009-11-11 |
| Other Details Language | Author name: Dr Ian McNicoll Organisation: Ocean Informatics, United Kingdom Email: ian.mcnicoll@oceaninformatics.com Date originally authored: 2009-11-11 |
| Other Details (Language Independent) |
|
| Keywords | fluid, io, input, balance |
| Lifecycle | AuthorDraft |
| Language used | en |
| Citeable Identifier | 1013.1.1449 |
| events | |
| Measurement Time | Measurement Time: The measurement, or estimation, of the volume of a specified fluid input at a specified point-in-time. |
| Measurement Interval | Measurement Interval: The measurement, or estimation, of the volume of a specified fluid input during a specified interval of time. Math. function: Actual |
| protocol | |
| Measurement Precision | Measurement Precision: Records the level of precision of the fluid input observation.
|
| Input Device | Input Device: The input device, for example a nasogastric tube or a jejunal catheter. Include: openEHR-EHR-CLUSTER.device.v1 and specialisations Exclude: All not explicitly included archetypes |
| Measurement Device | Measurement Device: Details of device used to measure the fluid input. Include: openEHR-EHR-CLUSTER.device.v1 and specialisations Exclude: All not explicitly included archetypes |
| data | |
| Route | Route: The delivery route of the fluid. For example: nasogastric tube; oral; intravenous or intraosseous. |
| Fluid | Fluid: Identification of the fluid ingested or administered. For example: Normal Saline; cup of tea; or parenteral nutrition. |
| Volume | Volume: The volume of fluid ingested or administered. Property: Volume Units:
|
| Comment | Comment: Additional narrative about the fluid input not captured in other fields. |
| Other contributors | Sam Heard, Ocean Informatics, Australia Heather Leslie, Ocean Informatics, Australia |
| Translators |