ARCHETYPE Fluid Input (openEHR-EHR-OBSERVATION.fluid_input.v1)

ARCHETYPE IDopenEHR-EHR-OBSERVATION.fluid_input.v1
ConceptFluid Input
DescriptionRecord of fluid being ingested by, or administered to, the subject.
UseUse to record details of fluid input as part of routine nursing care. Use to record details of individual fluid input activities, in order to allow fluid balance estimations. For example: "Oral", "Cup of Tea", 220ml; or 1 litre Normal Saline infusion. May also be used to record descriptive assessments of fluid input. A fluid balance chart will typically require a combination of OBSERVATION.fluid_output, OBSERVATION.fluid_balance and this archetype to capture all the required components.
MisuseNot to be used as a primary record of the fluid administration such as intravascular therapy or haemodialyisis. Not to be used to record fluid output. Use OBSERVATION.fluid_output for this purpose. Not to be used to record fluid balance calculations. Use OBSERVATION.fluid_balance for this purpose.
PurposeTo record details of fluid input, often used as part of fluid balance estimation.
References
Copyright© openEHR Foundation
AuthorsAuthor name: Dr Ian McNicoll
Organisation: Ocean Informatics, United Kingdom
Email: ian.mcnicoll@oceaninformatics.com
Date originally authored: 2009-11-11
Other Details LanguageAuthor name: Dr Ian McNicoll
Organisation: Ocean Informatics, United Kingdom
Email: ian.mcnicoll@oceaninformatics.com
Date originally authored: 2009-11-11
Other Details (Language Independent)
  • Current Contact: Heather Leslie, Ocean Informatics, heather.leslie@oceaninformatics.com
  • MD5-CAM-1.0.1: A5C8CEE87902DE504CA80CEB87EFE328
Keywordsfluid, io, input, balance
LifecycleAuthorDraft
Language useden
Citeable Identifier1013.1.1449
events
Measurement TimeMeasurement Time: The measurement, or estimation, of the volume of a specified fluid input at a specified point-in-time.
Measurement IntervalMeasurement Interval: The measurement, or estimation, of the volume of a specified fluid input during a specified interval of time.
Math. function: Actual
protocol
Measurement PrecisionMeasurement Precision: Records the level of precision of the fluid input observation.
  • Estimated [The fluid volume has been estimated.]
  • Measured [The fluid volume has been directly measured.]
  • Stated [The fluid input has been stated.]
Input DeviceInput Device: The input device, for example a nasogastric tube or a jejunal catheter.
Include:
openEHR-EHR-CLUSTER.device.v1 and specialisations
Exclude:
All not explicitly included archetypes
Measurement DeviceMeasurement Device: Details of device used to measure the fluid input.
Include:
openEHR-EHR-CLUSTER.device.v1 and specialisations
Exclude:
All not explicitly included archetypes
data
RouteRoute: The delivery route of the fluid.
For example: nasogastric tube; oral; intravenous or intraosseous.
FluidFluid: Identification of the fluid ingested or administered.
For example: Normal Saline; cup of tea; or parenteral nutrition.
VolumeVolume: The volume of fluid ingested or administered.
Property: Volume
Units:
  • >=0.0 ml
    Limit decimal places: 0
  • >=0.0 l
    Limit decimal places: 2
  • >=0.0 cc
    Limit decimal places: 1
  • fl oz
CommentComment: Additional narrative about the fluid input not captured in other fields.
Other contributorsSam Heard, Ocean Informatics, Australia
Heather Leslie, Ocean Informatics, Australia
Translators
  • Slovenian, Slovene: ?