| ARCHETYPE ID | openEHR-EHR-OBSERVATION.fluid_output.v1 |
|---|---|
| Concept | Fluid Output |
| Description | Record of fluid output by the subject. |
| Use | Use to record details of individual fluid output measurements or estimations as part of routine nursing care, often as part of fluid balance estimations. For example: "Urine", "150ml"; or "Aspiration", "50 ml". A fluid balance chart will typically require a combination of OBSERVATION.fluid_output, OBSERVATION.fluid_balance and this archetype to capture all the required components. |
| Misuse | Not to be used to record fluid input. Use OBSERVATION.fluid_input for this purpose. Not to be used to record fluid balance calculations. Use OBSERVATION.fluid_balance for this purpose. |
| Purpose | To record fluid output measurements or estimations, often used as part of fluid balance estimation. |
| References | |
| Copyright | © openEHR Foundation |
| Authors | Author name: Dr Ian McNicoll Organisation: Ocean Informatics, United Kingdom Email: ian.mcnicoll@oceaninformatics.com Date originally authored: 2009-11-11 |
| Other Details Language | Author name: Dr Ian McNicoll Organisation: Ocean Informatics, United Kingdom Email: ian.mcnicoll@oceaninformatics.com Date originally authored: 2009-11-11 |
| Other Details (Language Independent) |
|
| Keywords | fluid, io, balance, output |
| Lifecycle | AuthorDraft |
| Language used | en |
| Citeable Identifier | 1013.1.1444 |
| events | |
| Measurement Time | Measurement Time: The measurement, or estimation, of the volume of a specified fluid output at a specified point-in-time. |
| Measurement Interval | Measurement Interval: The measurement, or estimation, of the volume of a specified fluid output during a specified interval of time. For example: the amount of urine output over the last 4 hours. Math. function: Actual |
| protocol | |
| Measurement Precision | Measurement Precision: Records the level of precision of the fluid output observation.
|
| Output Device | Output Device: The output device. For example: a urinary catheter or a drain tube. Include: openEHR-EHR-CLUSTER.device.v1 and specialisations Exclude: All not explicitly included archetypes |
| Measurement Device | Measurement Device: Details of device used to measure the fluid output. Include: openEHR-EHR-CLUSTER.device.v1 and specialisations Exclude: All not explicitly included archetypes |
| data | |
| Fluid | Fluid: Identification of the fluid type or source. For example: urine; vomit or drain tube fluids. In a clinical application, if the same type of fluid is being observed from two or more sources such as multiple drains from the same wound, the fluid source may be described as “Drain 1” and “Drain 2”. |
| Volume | Volume: The volume of fluid output. Property: Volume Units:
|
| Fluid Details | Fluid Details: Details about the fluid output. For example: further details about the urine, such as description of the color and presence of sediment. Include: All not explicitly excluded archetypes |
| Comment | Comment: Additional narrative about the fluid output not captured in other fields. |
| Other contributors | Sam Heard, Ocean Informatics, Australia Heather Leslie, Ocean Informatics, Australia |
| Translators |